Wires-x Software
2021年10月8日Download here: http://gg.gg/w5rpc
*Wires-x Software Manual
*Wires X Software Manual
*Wires-x Software Update
*Wires X Repeaters
*Wires-x Software Windows 10
*Wires-x Software InstallationRelated searches
WIRES-X supports the C4FM digital and the clear and crisp voice technology enables high sound quality. By repeating C4FM digital data as it is via the Internet, users can enjoy clear voice communications even if they are thousands of miles away each other. We are not affiliated with any software maker, just offering a place to easily find downloads for a Mac Some of the programs you have to buy, others are free; have a.
*» wires-x latest version
*» wires-x software download
*» yeasu wires-x pc software download
*» wires-x software
*» wires-x pc software
*» wires-x software 1.5
*» download software wires-x
*» yaesu wires-x software download
*» download wires-x software
*» wires-x node software downloadlatest version of wires-x software at UpdateStar
*More WIRES-X
*More Apple Software Update 2.6.3.1 Apple Software Update is a software tool by Apple that installs the latest version of Apple software. It was originally introduced to Mac users in Mac OS 9. A Windows version has been available since the introduction of iTunes 7. more info...
*More UpdateStar Premium Edition 12.0.1923 UpdateStar 10 offers you a time-saving, one-stop information place for your software setup and makes your computer experience more secure and productive. more info...
*More Intel PROSet/Wireless Software 22.0.0.6 Installer package for driver version 11.5 and Intel PROSet/Wireless Tools version 11.5 supporting Intel(R) Wireless WiFi Link 4965AGN Mini Card and Intel(R) PRO/Wireless 3945ABG Network Connection Mini Card on Windows Vista operating … more info...
*More Opera Browser 76.0.4017.177 The latest Opera release brings forth a completely different look for the popular web browser, which definitely gives users a reason to tinker with its new features. more info...
*More Epson Software Updater 4.6.1
*More Microsoft .NET Framework 5.0.3 The Microsoft .NET Framework 4 Client Profile redistributable package installs the .NET Framework runtime and associated files that are required to run most client applications.The .NET Framework is Microsoft’s comprehensive and consistent … more info...
*More IObit Software Updater 3.4.0.1902 IObit Software Updater is an ad-free and light freeware that helps you update all outdated programs with just 1-click and also install all popular must-have programs easily. more info...
*More Adobe Flash Player ActiveX 34.0.0.105 Adobe Flash Player ActiveX enables the display of multimedia and interactive content within the Internet Explorer web browser. more info...
*More Software Informer 1.5.1344 Software Informer is a utility that has been designed specifically for those users who care to keep their applications functional and ready for any task that might arise. more info...latest version of wires-x software search results Descriptions containing latest version of wires-x software
*More Intel Processor Graphics 27.20.100.7989 Intel X3000 Chipset incorporates key features available in previous Intel Graphics versions like Dynamic Video Memory Technology (DVMT) as well as hardware acceleration for 3D graphics that utilize Microsoft DirectX* 9.0C and OpenGL* 1.5X. more info...
*More UpdateStar Premium Edition 12.0.1923 UpdateStar 10 offers you a time-saving, one-stop information place for your software setup and makes your computer experience more secure and productive. more info...
*More Realtek High Definition Audio Driver 6.0.9088.1REALTEK Semiconductor Corp. - 168.6MB - Freeware - Audio chipsets from Realtek are used in motherboards from many different manufacturers. If you have such a motherboard, you can use the drivers provided by Realtek. more info...
*More WinRAR 6.01 WinRAR is a 32-bit/64-bit Windows version of RAR Archiver, the powerful archiver and archive manager. WinRARs main features are very strong general and multimedia compression, solid compression, archive protection from damage, processing … more info...
*More Adobe Flash Player ActiveX 34.0.0.105 Adobe Flash Player ActiveX enables the display of multimedia and interactive content within the Internet Explorer web browser. more info...
*More Apple Software Update 2.6.3.1 Apple Software Update is a software tool by Apple that installs the latest version of Apple software. It was originally introduced to Mac users in Mac OS 9. A Windows version has been available since the introduction of iTunes 7. more info...
*More Skype 8.72.0.94 Skype is software for calling other people on their computers or phones. Download Skype and start calling for free all over the world. The calls have excellent sound quality and are highly secure with end-to-end encryption. more info...
*More Google Chrome 91.0.4472.77 Chrome is a web browser developed by Google. It is characterized by its speed and many innovative features. more info...
*More Java Update 8.0.2910.10 The Java SE Runtime Environment contains the Java virtual machine,runtime class libraries, and Java application launcher that arenecessary to run programs written in the Java programming language.It is not a development environment and … more info...
*More Microsoft .NET Framework 5.0.3 The Microsoft .NET Framework 4 Client Profile redistributable package installs the .NET Framework runtime and associated files that are required to run most client applications.The .NET Framework is Microsoft’s comprehensive and consistent … more info... Additional titles containing latest version of wires-x software
*More Apple Software Update 2.6.3.1 Apple Software Update is a software tool by Apple that installs the latest version of Apple software. It was originally introduced to Mac users in Mac OS 9. A Windows version has been available since the introduction of iTunes 7. more info...
*More Epson Software Updater 4.6.1
*More Intel PROSet/Wireless Software 22.0.0.6 Installer package for driver version 11.5 and Intel PROSet/Wireless Tools version 11.5 supporting Intel(R) Wireless WiFi Link 4965AGN Mini Card and Intel(R) PRO/Wireless 3945ABG Network Connection Mini Card on Windows Vista operating … more info...
*More AMD Software 20.12.1
*More Software Informer 1.5.1344 Software Informer is a utility that has been designed specifically for those users who care to keep their applications functional and ready for any task that might arise. more info...05/26/202105/11/202105/05/202104/30/202104/29/2021Most recent searches
*» 4mekey for ipad mini
*» controladro de tocuh pad dell
*» fork player 2.5 descargar
*» spreeder cx 破解下载
*» descargar java 7 para internet explorer
*» openocd gui windows
*» portal de myepson
*» truevision3d download
*» lunar client a télécharger
*» kodi 19.1 tv download
*» хроне бровсер
*» nokia mtp driver 1.0.8 0
*» netextender pobranie
*» cncjs download
*» msi 애프트버너
*» descargar lvsim ems 3.71
*» mercusys mw150us driver download
*» bcd3000 drivers software
*» 3d lara and horses
*» baixar logic usb display driver
WARNING! I recently found a non-US website that lists a number of messages as “WiRES-X” messages. They are not. They are “WiRES-II” messages. The two are incompatible. Introduced in 2002, support for WiRES-II was officially ended in 2017. The HRI-100 was used with WiRES-II.
The messages and codes below are those of WiRES-X PC software version 1.530 (current as of August 8th, 2020). If you see a different version listed, make sure you are looking at the right thing.
This page will attempt to deal with error codes as displayed on the WiRES-X PC software interface. CAUTION: These entries are user-submitted and are not official in any way. Interpret and use them at your own risk. Submitted entries must be accompanied by the submitter’s callsign, operating system and other pertinent information.
_____________________________________________________________________________
CHECK THE HEADER (IN PURPLE) IN EACH SECTION FOR THE PHYSICAL LOCATION OF EACH ERROR MESSAGE.
************************************************************************
CONTENTS, ALPHABETICALLY
*_*_* Call to Rejected No. (node number), In conf. *_*_* – LOG BOX 1
*_*_* Call to Rejected No. (node number) (Room connection) *_*_* LOG BOX 37
*_*_* Cancelled call in PDN standby *_*_* – LOG BOX 20
*_*_* Cancelled call to analog node or Analog & Digital room *_*_* – LOG BOX 6
*_*_* Can not accept own call *_*_* – LOG BOX 12
** Connect message: Digital transceiver frame response timeout – LOG BOX 23
Create Capture Buffer Failure code = 80004005 – LOG BOX 16
Digital PTT not ON recovery. One AMBE Out – LOG BOX 25
Digital PTT not ON reset. One AMBE Out – LOG BOX 27
Digital transceiver error reset code = 1030100 – LOG BOX 14
Digital transceiver error reset code 1040100 – LOG BOX 17
Digital transceiver error reset code = 1050100 – LOG BOX 5
Digital transceiver error reset code = 1050100 – LOG BOX 18
Digital transceiver error reset. code = 10E0C01 – LOG BOX 36
Digital transceiver error reset code = 11A0100 – LOG BOX 21
Digital transceiver error reset code = 1100100 – LOG BOX 33
Digital transceiver error reset code =1120100 – LOG BOX 4
Digital transceiver error reset code = 1240801 – LOG BOX 26
Direct Sound Create 8 Failed. Code = 88780078 – LOG BOX 32
** End sound: Digital transceiver frame response timeout – LOG BOX 22
Error: Connection Busy from XXXXX-XX (#####) – LOG BOX 34
Error: No answer from called PC * Disconnected * – LOG BOX 8
Error: No entry on ILS server * Disconnected * – LOG BOX 10
Error: Socket Communication Timeout – LOG BOX 7
Error: Socket Communication Timeout at call – LOG BOX 3
Error: Socket Communication Timeout at call – LOG BOX 13
HRI-200 Connect fail – WiRES ID Activation 3
List server response time-out – LOG BOX 11
*local host* ON AIR UNLOCK – LOG BOX 35
Not connect in room. Refresh failed. – LOG BOX 31
Not found the Audio device for the WiRES-X use – STATUS BAR 3
OFFLINE – Status Bar 4
ON Air Lock ON – LOG BOX 28
“ON-AIR LOCK” STATE – STATUS BAR 2
One AMBE Out – LOG BOX 2
(Other errors) – Errors in the User Monitoring Window 1
Return to room (____) last (____) count – LOG BOX 9
Server Access Error: “A connection with the server could not be established” – LOG BOX 19
Server Access Error: “The server name or address could not be resolved” – LOG BOX 24
Server or ID Not Found – WiRES ID Activation window 2
Transceiver communication device Removed. – LOG BOX 30
Transceiver not connected – STATUS BAR 1
Transceiver registration (reading Radio ID.) but nothing happens – WiRES ID Activation window 1
Transceiver TX Stop. Disconnect – LOG BOX 15
TX Timeout (over 3min). – LOG BOX 29
WARNING ! A connecting transceiver was changed from Simplex type to Repeater type. The WiRES-X software is rebooted in Repeater mode. – PAGE MIDDLE 3
WARNING ! A connecting transceiver was changed from Repeater type to Simplex type. The WiRES-X software is rebooted in Simplex (mobile transceiver) mode. – PAGE MIDDLE 2
WARNING ! Not found the Audio device for WiRES-X use. Please check the audio device and restart the WIRES-X application. – PAGE MIDDLE 4
WiRES-X ??????? – PAGE MIDDLE 1
WiRES-X cannot operate because unavailable transceiver setting. Please check transceiver setting. – STATUS BAR 5
************************************************************************
ERROR MESSAGES IN THE STATUS BAR
1. Message: Transceiver not connect(ed)
Submitted by K1KC Date: August 19, 2019
Cause: The WiRES-X software is not reading the radio.
Solution: Since there is more than one cause, check these solutions: 1. Make sure the transceiver is in the WiRES-X mode. 2. Make sure the transceiver is an approved node radio. 3. Wait for the transceiver to power up and be recognized by the software. 4. Make sure the transceiver has power supplied and is turned on. 5. If the transceiver is a repeater, make sure the repeater is set to ‘RPTR+HRI Mode’.
———————————————
2. Message: “ON-AIR LOCK” state.
Submitted by: K1KC Date: December 7, 2019 OS: Windows 10 Home V. 1909
Cause: The ON-AIR LOCK button was pressed during operation.
Solution: Press the LOCK button again to unlock.
———————————————-
3. Message: Not found the Audio device for the WiRES-X use.
Submitted by: K1KC Date: December 21, 2019 OS: Windows 10 Home Version 1909
Effect: No connection with the node radio was possible.
Cause: The PC did not load the audio drivers/devices for audio to pass between radio and computer.
Solution: (I’d like to say: ‘Strongly encourage Yaesu to adopt some other OS than Windows’). However, they have indicated that won’t be happening. Therefore, you must figure out how to do this. Until near the end of 2019, this was usually accomplished by a second re-booting of your Windows PC after an update. Now it has become more difficult. Good luck.
————————–
(another reporter): Submitted by: KN4VJR Date: April 12, 2020
OS: Windows 10 Home
Effect: No connection with the node radio was possible.
Cause: The computer does not have a microphone attached.
Solution: Do one of the options below and then restart the Wires-X program.
Option #1 – Install a computer microphone via the 1/8” microphone jack.Option #2 – Connect a USB microphone.Option #3 – Insert an 1/8” stereo male plug into the 1/8” microphone jack, the other end does not need to be connected. For example, a 1/8” Stereo male plug to a 1/4″ female adaptor worked for my setup. With this option, the computer for some reason thinks it is a microphone.(For some reason the computer needs to see that a microphone is connected.)
(another user reports): Try updating the Realtek microphone driver.
————————————————————————-
4. Message: OFFLINE
Submitted by: K0HCV Date: February 8, 2020 OS: Windows __
Effect: No connection to the listserver.
Cause: Multiple causes. Anything that prevents an Internet connection to the listservers can cause this error. It can be caused by the listservers themselves being offline. It can be caused when you have no Internet connection (which can be either short or long-lasting). Recently it has been suggested that lack of port forwarding of Port 10080 for PDN’s may be a cause.
Solution: Check the obvious things when you get this error. Make sure you actually have an active Internet connection to your WiRES-X PC. This is probably the #1 fault. Secondly, it IS possible the listservers are unavailable, but that is not likely. There is some redundancy there and if they ARE unavailable, it probably won’t last too long. Listservers DO require updates themselves so there are times they go offline, and they go offline without notice. Sometimes nodes that are already connected will stay connected but nodes attempting to connect cannot. This situation resolves itself in time.
The latest finding that Port 10080 not being forwarded can cause an offline condition (to a PDN) is new to us. I cannot confirm or deny this, but it seems very plausible.
*********************************
5. Message: WiRES-X cannot operate because unavailable transceiver setting. Please check transceiver setting.
Submitted by: K1KC Date: Aug. 8, 2020 OS: Windows 10
Effect: WiRES-X would not load properly.
Cause: The software did not like the transceiver settings for some reason.
Solution: This one is a little baffling. You may get this message when you are unable to actually make any changes to the transceiver setting…at least from the PC software. Most likely you will have to make changes from the transceiver touch screen or radio controls. If it is a repeater and you are operating on DC power, you may have to change to AC power to make any changes.
************************************************************************
ERROR MESSAGES IN THE LOG BOX
———————————————————
1. Message: *_*_* Call to Rejected No. (node number), In conf. *_*_*
Submitted by K0HCV Date: August 21, 2019
Cause: (Not determined yet)
Solution: One solution offered by Yaesu was to go to the PC software, under FILES, select SET DEFAULT, then OKAY. This returns the WIRES-X software to its initial state and shuts the program down. You will have to reboot.
2. Message: One AMBE out
Submitted by K0HCV Date: August 14, 2019
Cause: This error is believed to be caused by a non-Yaesu device such as a hotspot on the network, but this has not been confirmed.
Solution: We believe that eliminating the use of non-Yaesu digital devices may cure this issue. This has not been confirmed.
—————————-
3. Message: Error:Socket Communication Timeout at call (see additional response below under #7)
Submitted (elsewhere) by G4OXY
Effect: No audio, intermittent traffic, timer would start running for reason
Cause: RFI on frequency
Solution: Increase squelch level setting, separate antennas or do whatever is necessary to reduce RF in affected receiver
(Another report) – Same error message but the user was having trouble staying connected to a room. RFI once again appears to have been the cause.
Submitted by: K1KC (with thanks to WA4ASI) Date: May 20, 2021
—————————
4. Message: Digital transceiver error reset code = 1120100
Submitted by: K1KC Date: October 4, 2019 OS: Windows 10
Effect: No WiRES-X operationWires-x Software Manual
Cause: Power was removed from node radio
Solution: Restore power to node radio
——————————-
5. Message: Digital transceiver error reset code = 1050100
Submitted by: K1KC Date: October 4, 2019 OS: Windows 10
Effect: No WiRES-X operation
Cause: Node radio was turned off or power was removed to node radio
Solution: Restore power to node radio
———————————–
6. Message: * – * – * Cancelled call to analog node or Analog & Digital room * – *
Submitted by: K1KC Date: October 5, 2019 Updated March 1, 2021 OS: Windows 10 Pro
Effect: PDN would not connect to room
Cause: PDN was in PDN mode (digital only) and room called was in Mixed Mode, OR, node called was in analog mode.
Solution: Change PDN to HRI mode from PDN mode
———————————-
7. Message: Error: Socket Communication Timeout
Submitted by: K1KC Date: October 6, 2019 OS: windows 10 Pro
Effect: Communications with previously connected node or room lost
Cause: The previously connected node or room went offline. Apparently there is an exchange of ‘heartbeats’ or ‘pings’ or ‘keep me on the list’ packets between the listserver and your node while you have connections. If part of this exchange is missed or dropped, the system may think you are not available and cause a communication timeout error. This will usually self-correct but a manual reset does not hurt.
Solution: (Depends on your desires) Manually re-connect to node or room if it comes back online and if you do not have ‘Return To Room’ enabled, or connect to another node or room.
————————
(another reporter): It has also been suggested that it is an issue with your Internet Service Provider. Your ISP may think that too much activity is taking place on that TCP/IP port.
Comment: I believe it is tr
https://diarynote-jp.indered.space
*Wires-x Software Manual
*Wires X Software Manual
*Wires-x Software Update
*Wires X Repeaters
*Wires-x Software Windows 10
*Wires-x Software InstallationRelated searches
WIRES-X supports the C4FM digital and the clear and crisp voice technology enables high sound quality. By repeating C4FM digital data as it is via the Internet, users can enjoy clear voice communications even if they are thousands of miles away each other. We are not affiliated with any software maker, just offering a place to easily find downloads for a Mac Some of the programs you have to buy, others are free; have a.
*» wires-x latest version
*» wires-x software download
*» yeasu wires-x pc software download
*» wires-x software
*» wires-x pc software
*» wires-x software 1.5
*» download software wires-x
*» yaesu wires-x software download
*» download wires-x software
*» wires-x node software downloadlatest version of wires-x software at UpdateStar
*More WIRES-X
*More Apple Software Update 2.6.3.1 Apple Software Update is a software tool by Apple that installs the latest version of Apple software. It was originally introduced to Mac users in Mac OS 9. A Windows version has been available since the introduction of iTunes 7. more info...
*More UpdateStar Premium Edition 12.0.1923 UpdateStar 10 offers you a time-saving, one-stop information place for your software setup and makes your computer experience more secure and productive. more info...
*More Intel PROSet/Wireless Software 22.0.0.6 Installer package for driver version 11.5 and Intel PROSet/Wireless Tools version 11.5 supporting Intel(R) Wireless WiFi Link 4965AGN Mini Card and Intel(R) PRO/Wireless 3945ABG Network Connection Mini Card on Windows Vista operating … more info...
*More Opera Browser 76.0.4017.177 The latest Opera release brings forth a completely different look for the popular web browser, which definitely gives users a reason to tinker with its new features. more info...
*More Epson Software Updater 4.6.1
*More Microsoft .NET Framework 5.0.3 The Microsoft .NET Framework 4 Client Profile redistributable package installs the .NET Framework runtime and associated files that are required to run most client applications.The .NET Framework is Microsoft’s comprehensive and consistent … more info...
*More IObit Software Updater 3.4.0.1902 IObit Software Updater is an ad-free and light freeware that helps you update all outdated programs with just 1-click and also install all popular must-have programs easily. more info...
*More Adobe Flash Player ActiveX 34.0.0.105 Adobe Flash Player ActiveX enables the display of multimedia and interactive content within the Internet Explorer web browser. more info...
*More Software Informer 1.5.1344 Software Informer is a utility that has been designed specifically for those users who care to keep their applications functional and ready for any task that might arise. more info...latest version of wires-x software search results Descriptions containing latest version of wires-x software
*More Intel Processor Graphics 27.20.100.7989 Intel X3000 Chipset incorporates key features available in previous Intel Graphics versions like Dynamic Video Memory Technology (DVMT) as well as hardware acceleration for 3D graphics that utilize Microsoft DirectX* 9.0C and OpenGL* 1.5X. more info...
*More UpdateStar Premium Edition 12.0.1923 UpdateStar 10 offers you a time-saving, one-stop information place for your software setup and makes your computer experience more secure and productive. more info...
*More Realtek High Definition Audio Driver 6.0.9088.1REALTEK Semiconductor Corp. - 168.6MB - Freeware - Audio chipsets from Realtek are used in motherboards from many different manufacturers. If you have such a motherboard, you can use the drivers provided by Realtek. more info...
*More WinRAR 6.01 WinRAR is a 32-bit/64-bit Windows version of RAR Archiver, the powerful archiver and archive manager. WinRARs main features are very strong general and multimedia compression, solid compression, archive protection from damage, processing … more info...
*More Adobe Flash Player ActiveX 34.0.0.105 Adobe Flash Player ActiveX enables the display of multimedia and interactive content within the Internet Explorer web browser. more info...
*More Apple Software Update 2.6.3.1 Apple Software Update is a software tool by Apple that installs the latest version of Apple software. It was originally introduced to Mac users in Mac OS 9. A Windows version has been available since the introduction of iTunes 7. more info...
*More Skype 8.72.0.94 Skype is software for calling other people on their computers or phones. Download Skype and start calling for free all over the world. The calls have excellent sound quality and are highly secure with end-to-end encryption. more info...
*More Google Chrome 91.0.4472.77 Chrome is a web browser developed by Google. It is characterized by its speed and many innovative features. more info...
*More Java Update 8.0.2910.10 The Java SE Runtime Environment contains the Java virtual machine,runtime class libraries, and Java application launcher that arenecessary to run programs written in the Java programming language.It is not a development environment and … more info...
*More Microsoft .NET Framework 5.0.3 The Microsoft .NET Framework 4 Client Profile redistributable package installs the .NET Framework runtime and associated files that are required to run most client applications.The .NET Framework is Microsoft’s comprehensive and consistent … more info... Additional titles containing latest version of wires-x software
*More Apple Software Update 2.6.3.1 Apple Software Update is a software tool by Apple that installs the latest version of Apple software. It was originally introduced to Mac users in Mac OS 9. A Windows version has been available since the introduction of iTunes 7. more info...
*More Epson Software Updater 4.6.1
*More Intel PROSet/Wireless Software 22.0.0.6 Installer package for driver version 11.5 and Intel PROSet/Wireless Tools version 11.5 supporting Intel(R) Wireless WiFi Link 4965AGN Mini Card and Intel(R) PRO/Wireless 3945ABG Network Connection Mini Card on Windows Vista operating … more info...
*More AMD Software 20.12.1
*More Software Informer 1.5.1344 Software Informer is a utility that has been designed specifically for those users who care to keep their applications functional and ready for any task that might arise. more info...05/26/202105/11/202105/05/202104/30/202104/29/2021Most recent searches
*» 4mekey for ipad mini
*» controladro de tocuh pad dell
*» fork player 2.5 descargar
*» spreeder cx 破解下载
*» descargar java 7 para internet explorer
*» openocd gui windows
*» portal de myepson
*» truevision3d download
*» lunar client a télécharger
*» kodi 19.1 tv download
*» хроне бровсер
*» nokia mtp driver 1.0.8 0
*» netextender pobranie
*» cncjs download
*» msi 애프트버너
*» descargar lvsim ems 3.71
*» mercusys mw150us driver download
*» bcd3000 drivers software
*» 3d lara and horses
*» baixar logic usb display driver
WARNING! I recently found a non-US website that lists a number of messages as “WiRES-X” messages. They are not. They are “WiRES-II” messages. The two are incompatible. Introduced in 2002, support for WiRES-II was officially ended in 2017. The HRI-100 was used with WiRES-II.
The messages and codes below are those of WiRES-X PC software version 1.530 (current as of August 8th, 2020). If you see a different version listed, make sure you are looking at the right thing.
This page will attempt to deal with error codes as displayed on the WiRES-X PC software interface. CAUTION: These entries are user-submitted and are not official in any way. Interpret and use them at your own risk. Submitted entries must be accompanied by the submitter’s callsign, operating system and other pertinent information.
_____________________________________________________________________________
CHECK THE HEADER (IN PURPLE) IN EACH SECTION FOR THE PHYSICAL LOCATION OF EACH ERROR MESSAGE.
************************************************************************
CONTENTS, ALPHABETICALLY
*_*_* Call to Rejected No. (node number), In conf. *_*_* – LOG BOX 1
*_*_* Call to Rejected No. (node number) (Room connection) *_*_* LOG BOX 37
*_*_* Cancelled call in PDN standby *_*_* – LOG BOX 20
*_*_* Cancelled call to analog node or Analog & Digital room *_*_* – LOG BOX 6
*_*_* Can not accept own call *_*_* – LOG BOX 12
** Connect message: Digital transceiver frame response timeout – LOG BOX 23
Create Capture Buffer Failure code = 80004005 – LOG BOX 16
Digital PTT not ON recovery. One AMBE Out – LOG BOX 25
Digital PTT not ON reset. One AMBE Out – LOG BOX 27
Digital transceiver error reset code = 1030100 – LOG BOX 14
Digital transceiver error reset code 1040100 – LOG BOX 17
Digital transceiver error reset code = 1050100 – LOG BOX 5
Digital transceiver error reset code = 1050100 – LOG BOX 18
Digital transceiver error reset. code = 10E0C01 – LOG BOX 36
Digital transceiver error reset code = 11A0100 – LOG BOX 21
Digital transceiver error reset code = 1100100 – LOG BOX 33
Digital transceiver error reset code =1120100 – LOG BOX 4
Digital transceiver error reset code = 1240801 – LOG BOX 26
Direct Sound Create 8 Failed. Code = 88780078 – LOG BOX 32
** End sound: Digital transceiver frame response timeout – LOG BOX 22
Error: Connection Busy from XXXXX-XX (#####) – LOG BOX 34
Error: No answer from called PC * Disconnected * – LOG BOX 8
Error: No entry on ILS server * Disconnected * – LOG BOX 10
Error: Socket Communication Timeout – LOG BOX 7
Error: Socket Communication Timeout at call – LOG BOX 3
Error: Socket Communication Timeout at call – LOG BOX 13
HRI-200 Connect fail – WiRES ID Activation 3
List server response time-out – LOG BOX 11
*local host* ON AIR UNLOCK – LOG BOX 35
Not connect in room. Refresh failed. – LOG BOX 31
Not found the Audio device for the WiRES-X use – STATUS BAR 3
OFFLINE – Status Bar 4
ON Air Lock ON – LOG BOX 28
“ON-AIR LOCK” STATE – STATUS BAR 2
One AMBE Out – LOG BOX 2
(Other errors) – Errors in the User Monitoring Window 1
Return to room (____) last (____) count – LOG BOX 9
Server Access Error: “A connection with the server could not be established” – LOG BOX 19
Server Access Error: “The server name or address could not be resolved” – LOG BOX 24
Server or ID Not Found – WiRES ID Activation window 2
Transceiver communication device Removed. – LOG BOX 30
Transceiver not connected – STATUS BAR 1
Transceiver registration (reading Radio ID.) but nothing happens – WiRES ID Activation window 1
Transceiver TX Stop. Disconnect – LOG BOX 15
TX Timeout (over 3min). – LOG BOX 29
WARNING ! A connecting transceiver was changed from Simplex type to Repeater type. The WiRES-X software is rebooted in Repeater mode. – PAGE MIDDLE 3
WARNING ! A connecting transceiver was changed from Repeater type to Simplex type. The WiRES-X software is rebooted in Simplex (mobile transceiver) mode. – PAGE MIDDLE 2
WARNING ! Not found the Audio device for WiRES-X use. Please check the audio device and restart the WIRES-X application. – PAGE MIDDLE 4
WiRES-X ??????? – PAGE MIDDLE 1
WiRES-X cannot operate because unavailable transceiver setting. Please check transceiver setting. – STATUS BAR 5
************************************************************************
ERROR MESSAGES IN THE STATUS BAR
1. Message: Transceiver not connect(ed)
Submitted by K1KC Date: August 19, 2019
Cause: The WiRES-X software is not reading the radio.
Solution: Since there is more than one cause, check these solutions: 1. Make sure the transceiver is in the WiRES-X mode. 2. Make sure the transceiver is an approved node radio. 3. Wait for the transceiver to power up and be recognized by the software. 4. Make sure the transceiver has power supplied and is turned on. 5. If the transceiver is a repeater, make sure the repeater is set to ‘RPTR+HRI Mode’.
———————————————
2. Message: “ON-AIR LOCK” state.
Submitted by: K1KC Date: December 7, 2019 OS: Windows 10 Home V. 1909
Cause: The ON-AIR LOCK button was pressed during operation.
Solution: Press the LOCK button again to unlock.
———————————————-
3. Message: Not found the Audio device for the WiRES-X use.
Submitted by: K1KC Date: December 21, 2019 OS: Windows 10 Home Version 1909
Effect: No connection with the node radio was possible.
Cause: The PC did not load the audio drivers/devices for audio to pass between radio and computer.
Solution: (I’d like to say: ‘Strongly encourage Yaesu to adopt some other OS than Windows’). However, they have indicated that won’t be happening. Therefore, you must figure out how to do this. Until near the end of 2019, this was usually accomplished by a second re-booting of your Windows PC after an update. Now it has become more difficult. Good luck.
————————–
(another reporter): Submitted by: KN4VJR Date: April 12, 2020
OS: Windows 10 Home
Effect: No connection with the node radio was possible.
Cause: The computer does not have a microphone attached.
Solution: Do one of the options below and then restart the Wires-X program.
Option #1 – Install a computer microphone via the 1/8” microphone jack.Option #2 – Connect a USB microphone.Option #3 – Insert an 1/8” stereo male plug into the 1/8” microphone jack, the other end does not need to be connected. For example, a 1/8” Stereo male plug to a 1/4″ female adaptor worked for my setup. With this option, the computer for some reason thinks it is a microphone.(For some reason the computer needs to see that a microphone is connected.)
(another user reports): Try updating the Realtek microphone driver.
————————————————————————-
4. Message: OFFLINE
Submitted by: K0HCV Date: February 8, 2020 OS: Windows __
Effect: No connection to the listserver.
Cause: Multiple causes. Anything that prevents an Internet connection to the listservers can cause this error. It can be caused by the listservers themselves being offline. It can be caused when you have no Internet connection (which can be either short or long-lasting). Recently it has been suggested that lack of port forwarding of Port 10080 for PDN’s may be a cause.
Solution: Check the obvious things when you get this error. Make sure you actually have an active Internet connection to your WiRES-X PC. This is probably the #1 fault. Secondly, it IS possible the listservers are unavailable, but that is not likely. There is some redundancy there and if they ARE unavailable, it probably won’t last too long. Listservers DO require updates themselves so there are times they go offline, and they go offline without notice. Sometimes nodes that are already connected will stay connected but nodes attempting to connect cannot. This situation resolves itself in time.
The latest finding that Port 10080 not being forwarded can cause an offline condition (to a PDN) is new to us. I cannot confirm or deny this, but it seems very plausible.
*********************************
5. Message: WiRES-X cannot operate because unavailable transceiver setting. Please check transceiver setting.
Submitted by: K1KC Date: Aug. 8, 2020 OS: Windows 10
Effect: WiRES-X would not load properly.
Cause: The software did not like the transceiver settings for some reason.
Solution: This one is a little baffling. You may get this message when you are unable to actually make any changes to the transceiver setting…at least from the PC software. Most likely you will have to make changes from the transceiver touch screen or radio controls. If it is a repeater and you are operating on DC power, you may have to change to AC power to make any changes.
************************************************************************
ERROR MESSAGES IN THE LOG BOX
———————————————————
1. Message: *_*_* Call to Rejected No. (node number), In conf. *_*_*
Submitted by K0HCV Date: August 21, 2019
Cause: (Not determined yet)
Solution: One solution offered by Yaesu was to go to the PC software, under FILES, select SET DEFAULT, then OKAY. This returns the WIRES-X software to its initial state and shuts the program down. You will have to reboot.
2. Message: One AMBE out
Submitted by K0HCV Date: August 14, 2019
Cause: This error is believed to be caused by a non-Yaesu device such as a hotspot on the network, but this has not been confirmed.
Solution: We believe that eliminating the use of non-Yaesu digital devices may cure this issue. This has not been confirmed.
—————————-
3. Message: Error:Socket Communication Timeout at call (see additional response below under #7)
Submitted (elsewhere) by G4OXY
Effect: No audio, intermittent traffic, timer would start running for reason
Cause: RFI on frequency
Solution: Increase squelch level setting, separate antennas or do whatever is necessary to reduce RF in affected receiver
(Another report) – Same error message but the user was having trouble staying connected to a room. RFI once again appears to have been the cause.
Submitted by: K1KC (with thanks to WA4ASI) Date: May 20, 2021
—————————
4. Message: Digital transceiver error reset code = 1120100
Submitted by: K1KC Date: October 4, 2019 OS: Windows 10
Effect: No WiRES-X operationWires-x Software Manual
Cause: Power was removed from node radio
Solution: Restore power to node radio
——————————-
5. Message: Digital transceiver error reset code = 1050100
Submitted by: K1KC Date: October 4, 2019 OS: Windows 10
Effect: No WiRES-X operation
Cause: Node radio was turned off or power was removed to node radio
Solution: Restore power to node radio
———————————–
6. Message: * – * – * Cancelled call to analog node or Analog & Digital room * – *
Submitted by: K1KC Date: October 5, 2019 Updated March 1, 2021 OS: Windows 10 Pro
Effect: PDN would not connect to room
Cause: PDN was in PDN mode (digital only) and room called was in Mixed Mode, OR, node called was in analog mode.
Solution: Change PDN to HRI mode from PDN mode
———————————-
7. Message: Error: Socket Communication Timeout
Submitted by: K1KC Date: October 6, 2019 OS: windows 10 Pro
Effect: Communications with previously connected node or room lost
Cause: The previously connected node or room went offline. Apparently there is an exchange of ‘heartbeats’ or ‘pings’ or ‘keep me on the list’ packets between the listserver and your node while you have connections. If part of this exchange is missed or dropped, the system may think you are not available and cause a communication timeout error. This will usually self-correct but a manual reset does not hurt.
Solution: (Depends on your desires) Manually re-connect to node or room if it comes back online and if you do not have ‘Return To Room’ enabled, or connect to another node or room.
————————
(another reporter): It has also been suggested that it is an issue with your Internet Service Provider. Your ISP may think that too much activity is taking place on that TCP/IP port.
Comment: I believe it is tr
https://diarynote-jp.indered.space
コメント